Difference between revisions of "Motor protocol"
m (moved Spi motor protocol to Motor protocol) |
|
(No difference)
|
Revision as of 14:07, 21 May 2012
--- UNDER CONSTRUCTION!!! --- More info will be added.
Introduction
The protocol for the SPI_motor board will be explained on this page.
The addresses on the SPI bus are 7 bits wide. The lower bit specifies if the transaction is to be a read or a write. Write transactions have the lower bit cleared (0), read transactions have the lower bit set (1).
Each transaction on the SPI bus starts with the address of the board. The spi_lcd board will ignore any transactions on the SPI bus that do not start with its own address.
After the address a single byte indicates the "port" on the board that the data is written to. The software can thus define 256 ports on each board.
Also see the general SPI protocol
write ports
Some ports just set a single value. So writing more than one byte to such a port is redundant. Other ports are logically a stream of bytes. So writing more than one byte is encouraged.
The spi_motor boards defines several ports.
port | function |
---|---|
0x20 | Spin motor A in direction A with intensity <byte> |
0x21 | Spin motor A in direction B with intensity <byte> |
0x22 | Stop motor A |
0x30 | Spin motor B in direction A with intensity <byte> |
0x31 | Spin motor B in direction B with intensity <byte> |
0x32 | Stop motor B |
0x40 | set current position. |
0x41 | set target position. |
0x42 | set relative position. |
0x43 | set stepdelay. (in tenths of a millisecond, default 200: 20ms between steps). |
0x44 | Set number of driven coils. Writing 0x00 means driving one coil, other values mean driving two coils |
0xf0 | change address. |
read ports
The spi_motor boards defines the following read ports:
port | function |
---|---|
0x01 | identification string. (terminated with 0). |
0x02 | read eeprom (serial number). |
examples
read identification
read the identification string of the board. (spi_motor)
data sent | data recieved | explanation |
---|---|---|
0x91 | xx | select destination with address 0x90 for READ. |
0x01 | xx | identify |
xx | 0x73 | 's' |
xx | 0x70 | 'p' |
xx | 0x69 | 'i' |
xx | ... | etc. |
move stepper to step 0x1234
data sent | data recieved | explanation |
---|---|---|
0x88 | xx | select destination with address 0x88 for WRITE |
0x41 | xx | port 0x41: set target position |
0x34 | xx | low byte |
0x12 | xx | high byte. |